DURKOPP ADLER 745-34-2 Operating Instructions Manual page 19

Sewing unit for runstitching of piped flap and welt pocket openings and pocket corners
Hide thumbs Also See for 745-34-2:
Table of Contents

Advertisement

1
2
Changing the needles
3
Caution: Danger of injury!
Switch the main switch off.
Change the needles only with the main switch switched off.
Risk of injuries from cuts!
Do not reach into the area of the center knife 3 when changing the
needles.
Swing the folding station aside (see chapter 2.1)
The needles are freely accessible.
Loosen screw 2 and remove the needle from the needle holder 1.
Push the new needle into the drill-hole of the needle holder 1 as far
as it will go.
ATTENTION!
Seen from the operator's side the hollow groove 4 of the left needle
must point to the left and the hollow groove 5 of the right needle
must point to the right (see sketch).
Tighten screw 2.
ATTENTION!
After changing to another needle size the needle protection on the
hook has to be readjusted (see Service Instructions).
Note:
The standard needle size of class 745-34-2 is Nm 100.
4
5
1
17