2.15.2.2 Sewing with light barrier
When sewing in flaps the seam beginning and seam end are
recognized by the light barrier.
Positioning the flap
The positioning marks 6 on the folder limit the sewing area for the
attaching of flaps.
–
Always position the flaps within the marked area.
ATTENTION!
If the flap is positioned outside of the marked area, the display of the
control unit indicates the following error message.
Info line
1
Error of light barrier for flaps
Correction of seam beginning and seam end
The correction of seam beginning (NA) and seam end (NE) when
sewing with light barrier occurs in the pocket correction program (see
Programming Instructions, chapter 6.4).
39