58
Caution: Danger of injury!
Do not reach into the working area of the positioning device when
triggering the individual steps of the positioning process.
Positioning and starting the sewing cycle
1.
Align the jacket front part at the positioning marks 12 and 16.
The positioning marks (e.g. thin adhesive tape) serve for the
rough positioning of the jacket front part.
Right pedal: Picking up the "pocket bag".
2.
Position the pocket bag 9 with facing 8 at the stop 13 of plate 15.
Align pocket bag 9 at positioning mark 14 (e.g. thin adhesive tape)
in sewing direction.
3.
Step forward on the right pedal.
The gripper 11 lowers onto plate 15.
The needles of the gripper 11 run out and seize the pocket bag 9.
Note
The procedure can be undone by stepping the right pedal backward
once again.
4.
Step back on the left pedal and hold it stepped down.
The feeding device 10 opens.
5.
Position the upper side of breast welt 2 at the stops 1 and 3.
6.
Step forward on the left pedal.
The feeding device 10 closes and clamps the breast welt 2.
7.
Step forward on the left pedal.
The positioning device 10 swivels with breast welt 2 in alignment
position.
8.
Align jacket front part to breast welt 2 as per pattern.
9.
When equipped with vacuum:
Step forward on the left pedal.
The vacuum is switched on.
Note
The procedure can be undone by stepping the left pedal back once
again.
10. Step forward on the left pedal.
The feeding device 10 turns the breast welt 2.
The gripper 11 runs to the loading area and places the pocket bag
9 on the jacket front part.
11. Step forward on the left pedal.
The transport carriage runs to the loading area.
The feeding clamps lower.
The flap clamp 17 opens.
The positioning device 10 places the turned breast welt 2 on the
left feeding clamp.
The flap clamp 17 closes and clamps the breast welt 2.
The positioning device 10 swivels back to the basic position.
The vacuum is switched off automatically.