CHAPTER 7 EXTERNALS/AUXILIARY MECHANISMS
D. Control Panel PCB
Note:
You must adjust the VR for intensity
and AE (PC420/430/FC220) after
replacing the control panel PCB.
1. Detaching the Control Panel PCB
1) Detach the body cover.
2) Disconnect the three connectors
3) Hold the flat cable
hands, and detach them from the
connector by lifting them straight up.
4) Disengage the hook
the control panel PCB
up.
7-14
COPYRIGHT © 1998 CANON INC.
.
with both
, and detach
by pulling it
CANON PC400/420/430,FC200/220 REV.0 JAN.1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
Figure 7-201D