Click Port > PoE. The PoE Summary Page opens.
Figure 3-19 Port PoE Summary Page
The Port PoE Summary Page contains the following fields:
Table 3-14 Port PoE Summary Page item description
Item
State
Device
Power
Power
Max(watts)
Display
Power
Used(watts)
Power
Free(watts)
State
Ports
Mode
Power
Display
Power
Max(watts)
Power
Used(watts)
Indicates the power source status. The possible field values are:
On: Indicates that the power supply unit is functioning.
Off: Indicates that the power supply unit is not functioning.
Faulty: Indicates that the power supply unit is functioning, but an error
has occurred. For example, a power overload or a short circuit.
Indicates the maximum amount of power the switch can supply. The field
value is displayed in Watts.
Indicates the actual amount of power currently used by the switch. The field
value is displayed in Watts.
Indicates the amount of additional power currently available to the switch.
The field value is displayed in Watts.
Indicates if the port is enabled to deliver power to powered devices. The
possible field values are:
Enable: Indicates the switch is delivering power. This is the default.
Disabled: Indicates the switch is not delivering power.
Indicates the port power mode. The possible field values are:
Auto: Power is automatically allocated to the port, according to port
number. Lower numbered ports are assigned a higher priority for power
delivery. This is the default.
Guarantee: Power is guaranteed to the selected port, provided that the
power is available. This setting overrides the priority assigned to lower
port numbers by the auto mode.
Indicates the maximum amount of power available to the interface. The field
value is displayed in Watts.
Indicates the actual amount of power currently used by the interface. The
field value is displayed in Watts.