Circuit Breaker - Honda EB12D Owner's Manual

Hide thumbs Also See for EB12D:
Table of Contents

Advertisement

Circuit Breaker
The circuit breaker protects the individual
circuit protectors
and the 50A
120/24OV receptacle.
The circuit breaker wil automatically
switch OFF if
there is a short circuit
or a significant
overload
of the generator
at the
receptacle,
or if the ground-fault
circuit
interrupter
(GFCI) detects
a
ground-fault
current.
Check the following
if the circuit
breaker switches
OFF automatically:
l
When the GFCI RESET button
is extended
(page 14):
-
Unplug all appliances
from the receptacle
and check the appliance
for any defects as described
in TROUBLESHOOTING
(page 54).
After making
repairs, push the GFCI RESET button then turn the
circuit breaker ON.
l
When the GFCI RESET button is not extended:
-
Check that the appliance
is working
properly
and does not exceed
the rated load capacity
of the circuit
before switching
the circuit
breaker ON again.
The circuit breaker may be used to switch the generator
power on or off.
GFCI RESET BUlTON
CIRCUIT BREAKER
\
/