Circuit Breaker

The circuit breaker will automatically switch OFF if there is a short
circuit or a significant overload of the generator at the receptacle, or if
the ground fault circuit interrupter (GFCI) detects a ground fault
current.
Check the following if the circuit breaker switches OFF automatically:
When the GFCI RESET button is extended (page 18):
Unplug all appliances from the receptacles and check the
appliance for any defects as described in TROUBLESHOOTING
(page 47).
After making repairs, push the GFCI RESET button then turn the
circuit breaker ON.
When the GFCI RESET button is not extended:
Check that the appliance is working properly and does not exceed
the rated load capacity of the circuit before switching the circuit
breaker ON again.
The circuit breaker may be used to switch the generator power on or
off.