Maintenance Enhancements
Change to Permanent Error Alarm
Beginning with Release 4.2, the most recent permanent error
alarm is not shown on the System Error Log menu screen but
is available as an option from that screen. For details, refer to
the Maintenance section of the technician guide, Installation,
Programming and Maintenance.
Enhanced Extension Information Report
Beginning with Release 4.2, the Extension Information
Report includes the Extension Status (ESS) and supervisory
mode for each extension.
Release 5.0 Enhancements
Release 5.0 includes all Release 4.2 functionality plus the
enhancements listed below.
Computer Telephony Integration (CTI)
Beginning with Release 5.0, a PassageWay
Services CTI link from the MERLIN LEGEND Communications
System to a LAN server running Novell
allows Lucent Technologies-certified telephony applications to
control MLX and analog multiline telephone (BIS only)
operations that are monitored by the applications. The physical
connection for the CTI link is an MLX port on a 008 MLX or 408
MLX module on the MERLIN LEGEND Communications
System control unit and an ISDN link interface card plugged into
the customer's server. The feature is available for Hybrid/PBX
mode systems only.
System Requirements for CTI link
Refer to Chapter 2 of the Network Manager's Guide for detailed
installation instructions.
The following equipment and software are required:
An Intel i386, Intel i486, or Pentium class computer with at least
16 megabytes of RAM. Additional memory may be needed if
additional applications will be running on the server machine.
NetWare Version 4.10 or Version 3.12
5 megabytes of disk space available on the SYS (system)
volume
Telephony Services for NetWare software, Releases 2.21 or
later, installed
An Eicon/G. Diehl SCOM card for the CTI link
A free 8- or 16-bit ISA slot for the Eicon/G. Diehl SCOM card
System software Release 5.0 or later installed on the MERLIN
LEGEND Communications system
The MERLIN LEGEND configured in Hybrid/PBX mode
An MLX port board (using firmware Version 28 or later, except
Version 29) installed in the MERLIN LEGEND
NOTE:
The 008 MLX and 408 MLX modules must have firmware
vintage other than 29. If the module has firmware 29,
administering a CTI link on the module is prevented. An earlier
or later vintage firmware is supported.
®
Telephony
®
®
NetWare
software
Issue 2
January 1998
Page 16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MERLIN LEGEND Release 6.0 and is the answer not in the manual?

Table of Contents