Mechanical Specifications; Environmental Specifications - Fluke 374 Calibration Manual

Clamp meter
Hide thumbs Also See for 374:
Table of Contents

Advertisement

374/375/376
Calibration Manual

Mechanical Specifications

Size (L x W x H) ..................................... 246 mm x 83 m x 43 mm
Weight..................................................... 388 g
Jaw Opening ........................................... 34 mm
Flexible Current Probe Diameter ............ 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector) .............. 1.8 m

Environmental Specifications

Operating Temperature........................... -10 C – +50 C
Storage Temp ......................................... -40 C – +60 C
Operating Humidity ................................. Non condensing (< 10 C)
Operating Altitude ................................... 3000 meters
Storage Altitude ...................................... 12,000 meters
EMC ........................................................ EN 61326-1:2006
Temperature Coefficients........................ Add 0.1 x specified accuracy for each degree C above
Safety Specifications
Safety Compliance.................................. CAN/CSA-C22.2 No. 61010-1-04
Agency Approvals ...................................
Batteries.................................................. 2 AA, NEDA 15A, IEC LR6
8
90 % RH (at 10 C – 30 C)
75 % RH (at 30 C – 40 C)
45 % RH (at 40 C – 50 C)
28 C or below 18 C
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
P
)
;
®
,
,

Advertisement

Table of Contents
loading

This manual is also suitable for:

375376

Table of Contents