Fluke 3000 FC Manual

Fluke 3000 FC Manual

Wireless multimeter
Hide thumbs Also See for 3000 FC:

Advertisement

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
3000 FC
Wireless Multimeter
Users Manual
May 2014, Rev. 1, 9/16
© 2014-2016 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 3000 FC

  • Page 1 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 3000 FC Wireless Multimeter Users Manual May 2014, Rev. 1, 9/16 © 2014-2016 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ........................1 How to Contact Fluke ..................... 1 Safety Information ......................1 Hazardous Voltage ......................5 Test Lead Alert ....................... 5 Battery Saver (Sleep Mode) ................... 5 Wireless Radio ....................... 5 MIN MAX AVG Record Mode ..................6 Display Hold ........................
  • Page 4 3000 FC Users Manual Wireless Radio Setup ....................13 Pair with Fluke Connect App ..................14 Pair with Wireless Test Tools ..................14 Disconnect the Wireless Radio ................. 17 Basic Measurements ..................... 17 AC and DC Voltage Measurements ................17 Volts/Hertz Ratio .......................
  • Page 5: Introduction

    Introduction  Warning To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the Product. The 3000 FC Wireless Multimeter (the Product) is a True-rms Digital Multimeter. Safety Information The Product complies with: •...
  • Page 6 3000 FC Users Manual A Warning identifies conditions and procedures that are • Do not touch voltages >30 V ac rms, 42 V dangerous to the user. A Caution identifies conditions ac peak, or 60 V dc. and procedures that can cause damage to the Product or •...
  • Page 7 Wireless Multimeter Safety Information • • Replace the batteries when the low Keep fingers behind the finger guards on battery indicator shows to prevent the probes. incorrect measurements. • Do not touch the probes to a voltage • The battery door must be closed and source when the test leads are locked before you operate the Product.
  • Page 8 3000 FC Users Manual Table 1. Symbols Symbol Description Symbol Description WARNING. HAZARDOUS VOLTAGE. Risk of electric   WARNING. RISK OF DANGER. shock.  Consult user documentation.  Minimum fuse interrupt rating. Conforms to relevant Australian Safety and EMC ...
  • Page 9: Hazardous Voltage

    • to make sure the test leads are in the correct terminals. A mobile device. Use the Fluke Connect app to view measurements remotely, save to Fluke Cloud™ Battery Saver (Sleep Mode) storage, and share the information with your team.
  • Page 10: Min Max Avg Record Mode

    3000 FC Users Manual Push .  and Max show at the top of the MIN MAX AVG Record Mode display. The measurement in the display is the The MIN MAX AVG record mode records the minimum maximum value measured. It changes only when a and maximum input values, and calculates a running new maximum value is sensed.
  • Page 11: Display Hold

    Wireless Multimeter Display Hold Display Hold Yellow Button Push the yellow button ( ) to set the Product to a  Warning different measurement function. The different functions To prevent possible electrical shock, fire, or are shown in yellow around the rotary switch. Frequency, personal injury, do not use the HOLD mV ac, capacitance, diode test, and mA dc are functions function to measure unknown potentials.
  • Page 12: Manual And Auto Range

    3000 FC Users Manual Manual and Auto Range Power-Up Options The Product can be set to manual or auto range. In To set a power-up option, hold down the button shown in autorange, the Product sets the range so the input is Table 2 while you turn on the Product.
  • Page 13: Features

    Wireless Multimeter Features Features Tables 3 through 5 are lists of Product features with descriptions. Table 3. Inputs gxr001.eps Terminal Description mA - Input for 3.00 mA to 400.0 mA current measurements and current frequency.  COM - Return terminal for all measurements. ...
  • Page 14 3000 FC Users Manual Table 4. Rotary Switch Positions Switch Function Position DC voltage from 1 mV to 1000 V. Push to measure frequency from 2 Hz to 99.99 kHz. AC voltage measurement from 60.0 mV to 1000 V. Push to measure frequency from 2 Hz to 99.99 kHz.
  • Page 15 Wireless Multimeter Features Table 5. Pushbuttons Switch Button Function Position Selects frequency. Selects frequency. Selects ac millivolts. Selects capacitance. Selects diode test. Push once to select dc milliamps. Push twice to select ac frequency. Sets the Product to manual range and scrolls through each range. Push for 1 second to set ...
  • Page 16 • In App mode, sends the measurement to the Fluke Connect App on mobile device. • Push and hold for 1 second to turn off the radio when radio is on. This function stays in ac or dc when the function switch is moved to another position and back to this function. Even when turned to off and back to this function.
  • Page 17: Ac Zero Input Behavior Of True-Rms Meters

    True-rms meter specifications are only good for 1 % to ® 100 % of range. Non-zero digits that are shown on a connection to a test tool or the Fluke Connect app on your mobile device. True-rms meter when the test leads are open or are shorted are possible.
  • Page 18: Pair With Fluke Connect App

    Auto When the Product radio is set to the App (send) mode, 24.14 you can use the Fluke Connect app on a mobile device to view, save, and share measurements. To pair with the Fluke Connect app: Turn on the Product (the radio is off at the initial power on).
  • Page 19 Wireless Multimeter Wireless Radio Setup To start the discovery procedure: When the discovery procedure is complete: • the  icon shows on the display Push  to highlight the Tools (receive) option. • display updates to show a list of test tools with the ID Push ...
  • Page 20 3000 FC Users Manual You can select up to 3 test tools and show their When in the Tool (receive) mode: measurements on the Product display. The Product stays • display updates to show the live measurement of the in the test tool selection mode for approximately selected test tool (up to 3) 2 minutes.
  • Page 21: Disconnect The Wireless Radio

    Wireless Multimeter Basic Measurements Disconnect the Wireless Radio Basic Measurements You can use any one of these methods to disconnect a  Warning test tool radio from the Product. To prevent possible electrical shock, fire, or • Turn off the test tool. personal injury, disconnect power and discharge all high-voltage capacitors before •...
  • Page 22 3000 FC Users Manual Volts AC Volts DC Millivolts DC gxr002.eps Figure 1. AC and DC Voltage Measurements...
  • Page 23: Volts/Hertz Ratio

    Wireless Multimeter Basic Measurements Volts/Hertz Ratio Volts/Hz The Product can show the ratio of volts to frequency of an ac signal. Set the Product as shown in Figure 2 to show Volts/Hertz ratio. When the Product is set to the Volts/Hz function, the Volt/Hz voltage range is set to manual.
  • Page 24: Resistance Measurements

    3000 FC Users Manual Resistance Measurements  Warning To prevent possible electrical shock, fire, or personal injury, disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction. The Product sends a small current through the circuit for resistance measurements.
  • Page 25: Capacitance Measurements

    Wireless Multimeter Basic Measurements Capacitance Measurements  Warning To prevent possible electrical shock, fire, or personal injury, disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction. Capacitance ranges are 1,000 nF, 10.00 μF, 100.0 μF, and 9999 μF.
  • Page 26: Continuity Test

    3000 FC Users Manual Continuity Test  Warning To prevent possible electrical shock, fire, or personal injury, disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction. The continuity test uses a beeper that sounds when a closed circuit is sensed.
  • Page 27: Ac Or Dc Current Measurements

    Wireless Multimeter Basic Measurements AC or DC Current Measurements Turn off circuit power, break the circuit, put the Product in series, and then turn on circuit power.  Warning The current ranges are 60.00 mA and 400.0 mA. Set the To prevent possible electrical shock, fire, or Product as shown in Figure 6 to measure ac and dc personal injury:...
  • Page 28 3000 FC Users Manual gxr007.eps Figure 6. AC and DC Current Measurements...
  • Page 29: Diode Test

    Wireless Multimeter Basic Measurements Diode Test In a circuit, a good diode has a forward-bias measurement of 0.5 V to 0.8 V. A reverse-bias  Warning measurement includes the resistance of other pathways To prevent possible electrical shock, fire, or between the probes.
  • Page 30 3000 FC Users Manual Forward Bias Reverse Bias Good Diode Good Diode Bad Diode Bad Diode OPEN BEEP and Shorted gxr006.eps Figure 7. Diode Test...
  • Page 31: Frequency Measurement

    Wireless Multimeter Basic Measurements Frequency Measurement Set up the Product as shown in Figure 8 to measure frequency. A frequency measurement is a count of the number of times an ac voltage or current signal passes through a threshold point each second. The Product autoranges to one of four frequency ranges: 99.99 Hz, 999.9 Hz, 9.999 kHz, and 99.99 kHz.
  • Page 32 3000 FC Users Manual AC/DC Voltage Frequency AC Current Frequency gxr008.eps Figure 8. Frequency Measurement...
  • Page 33: Maintenance

    Wireless Multimeter Maintenance Maintenance Dry each terminal with canned air to push the water and detergent out of the terminals. Warning Warning To prevent a possible electrical shock or To prevent electrical shock or personal personal injury: injury, remove the test leads and all input •...
  • Page 34: Battery And Fuse Replacement

    3000 FC Users Manual Battery and Fuse Replacement  Warning To prevent possible electrical shock, fire, or personal injury: • Replace a blown fuse with exact replacement only for continued protection against arc flash. • Use only specified replacement fuses.
  • Page 35 Wireless Multimeter Maintenance To replace the batteries: To replace the fuse: Turn off the Product and remove all test leads. Turn off the Product and remove all test leads. Lift the tilt stand up as shown in Figure 10. As shown in Figure 10, remove six screws from the case bottom.
  • Page 36 3000 FC Users Manual gxr010.eps Figure 10. Battery and Fuse Replacement...
  • Page 37: Service And Parts

    Battery Door Assembly (includes tilt stand) 4207624 Gasket, Battery Door 4137532 Test Lead Set TL175 Alligator Clip, Black AC175 Alligator Clip, Red 3000 FC DMM Quick Reference Guide 4231002 3000 FC DMM Safety Information 4231677 To ensure safety, use exact replacement only. ...
  • Page 38 3000 FC Users Manual 3000 FC Battery Quick Reference Guide Door Battery AA x 1.5 V TL175 Test Lead Set 3000 FC Safety Information Fuse 440 mA 1000 V, Fast AC175 Threaded Alligator Clips gxr012.eps Figure 11. Replacement Parts...
  • Page 39 Wireless Multimeter Service and Parts Table 7. Accessories Item Description TPAK ToolPak Magnetic Hanger FLK-A3000 FC a3000 FC Wireless AC Clamp – Measure ac current to 400 amps FLK-A3001 FC a3001 FC Wireless iFlex – Measures ac current to 2500 amps FLK-A3002 FC a3002 FC Wireless AC/DC Clamp –...
  • Page 40: Specifications

    3000 FC Users Manual Specifications Maximum voltage between any Terminal and Earth Ground ......... 1000 V Frequency Overload Protection ......≤10 V-Hz  Fuse Protection for mA inputs ....... 0.44 A, 1000 V, IR 10 kA Display Update rate ............4/sec Volts, amps, ohms, ..........
  • Page 41 Wireless Multimeter Specifications Safety General..............IEC 61010-1: Pollution Degree 2 Measurement ............IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V Electromagnetic Compatibility (EMC) International ............IEC 61326-1: Portable Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
  • Page 42: Ac Voltage

    3000 FC Users Manual For all specifications: Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).
  • Page 43: Dc Voltage, Continuity, Resistance, Diode Test, And Capacitance

    Wireless Multimeter Specifications DC Voltage, Continuity, Resistance, Diode Test, and Capacitance Function Range Resolution Accuracy  600.0 mV 0.1 mV 0.09 % + 2 6.000 V 0.001 V 60.00 V 0.01 V 0.09 % + 2  600.0 V 0.1 V 1000 V 0.15 % + 2 600 Ω...
  • Page 44: Ac And Dc Current

    3000 FC Users Manual AC and DC Current Function Range Resolution Accuracy  60.00 mA 0.01 mA 1.5 % + 3 (45 Hz to 1 kHz) 0.1 mA 400.0 mA 60.00 mA 0.01 mA 0.5 % + 3  400.0 mA 0.1 mA...
  • Page 45: Frequency Counter Sensitivity

    Wireless Multimeter Specifications Frequency Counter Sensitivity Typical Sensitivity (RMS Sine Wave) [1] [2] Input Range 2 Hz to 45 Hz 45 Hz to 10 kHz 10 kHz to 20 kHz 20 kHz to 50 kHz 50 kHz to 100 kHz 0.5 V 0.6 V 1.0 V...
  • Page 46: Input Characteristics

    3000 FC Users Manual Input Characteristics Common Mode Overload Input Impedance Function Rejection Ratio Normal Mode Rejection Protection (nominal) (1 kΩ unbalance)  1100 V rms >10 MΩ <100 pF >120 dB at dc, 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz ...

Table of Contents