ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D
Air-flow cooling
ST15150DC drives
differential wide (SCA)
Card
Component
KYHX
Polar
KYHX
Writer
KYHX
CSAW
KYHX
Pike
KYHX
Driver
HDA housing
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocities were 0.61 msec
(120 lfpm) and inlet air temperature to the drive was 30°C (86°F), plus a 5°C
temperature rise in the test enclosure (35°C ambient local to the drive).
The maximum allowable HDA case temperature is 60°C.
1
Figure 12. KYHX temperature measurement locations
Reference
case temperature (°C)
1
2
3
4
5
Figure 13
2
3
4
29
MTBF
800k hours
48
64
47
52
60
5