ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D
Air-flow cooling
ST15150ND drives
differential
Card
Component
LYHX
Polar
LYHX
Writer
LYHX
CSAW
LYHX
Pike
LYHX
Driver
HDA housing
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocities were 0.61
msec (120 lfpm) and inlet air temperature to the drive was 30°C (86°F),
plus a 5°C temperature rise in the test enclosure (35°C ambient local to
the drive).
The maximum allowable HDA case temperature is 60°C.
1
Figure 8. LYHX temperature measurement locations
Reference
1
2
3
4
5
Figure 13
2
3
4
MTBF
800k hours
case temperature (°C)
48
64
47
52
60
5