26
ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D
Air-flow cooling
ST15150W drives
single-ended wide
Card
Component
MYHX
Polar
MYHX
Writer
MYHX
CSAW
MYHX
Pike
MYHX
Driver
HDA housing
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocities were 0.61 msec
(120 lfpm) and inlet air temperature to the drive was 30°C (86°F), plus a 5°C
temperature rise in the test enclosure (35°C ambient local to the drive).
The maximum allowable HDA case temperature is 60°C.
1
Figure 9. MYHX temperature measurement locations
Reference
1
2
3
4
5
Figure 13
2
3
4
MTBF
800k hours
case temperature (°C)
48
64
47
52
60
5