ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D
Air-flow cooling
ST15150WD drives
differential wide
Card
Component
NYHX
Polar
NYHX
Writer
NYHX
CSAW
NYHX
Pike
NYHX
Driver
HDA housing
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocities were 0.61 msec
(120 lfpm) and inlet air temperature to the drive was 30°C (86°F), plus a 5°C
temperature rise in the test enclosure (35°C ambient local to the drive).
The maximum allowable HDA case temperature is 60°C.
1
Figure 10. NYHX temperature measurement locations
Reference
1
2
3
4
5
Figure 13
2
3
4
MTBF
800k hours
case temperature (°C)
48
64
47
52
60
5
27