Relay Output
The VIP XD has a relay output for switching external units such as lamps or sirens. This relay
output can be activated manually during a connection session with the VIP XD. The output can
also be configured to automatically activate sirens or other alarm units in response to an
alarm signal. The relay output is also located on the orange terminal block (see
Section 8.6 Terminal Block, page 66).
CAUTION!
!
The maximum rating of the relay contact is 30 V and 2 A (SELV).
DOC | V4.0 | 2009.06
Connect the lines to the appropriate terminals of the orange terminal block (R) and
check that the connection is secure.