20 s
Value Range
10 s, 20 s, 30 s, 40 s, 60 s, 120 s
Programming Manual References
[508] DISA Ring Time before Intercept
Feature Manual References
1.1.41 Direct Inward System Access (DISA)
1.1.68 Intercept Routing
Timers—DISA Ring Time after Intercept
Selects the length of time to ring the destination extension when a DISA call is redirected to the intercept
destination after the time specified in Timers—DISA Ring Time before Intercept on this screen expires.
When the destination extension does not answer the call within the preprogrammed time period, the call is
disconnected.
Default
20 s
Value Range
10 s, 20 s, 30 s, 40 s, 60 s, 120 s
Programming Manual References
[509] DISA Ring Time after Intercept
Feature Manual References
1.1.41 Direct Inward System Access (DISA)
1.1.68 Intercept Routing
Timers—Intercept Time for Internal DISA
Selects the length of time the PBX keeps detecting DTMF signals after receiving a call using DISA when no
DISA OGM is recorded.
Default
3 s
Value Range
3 s, 6 s, 9 s
Programming Manual References
[515] Intercept Time for Internal DISA