Dss Console Jack Assignment - Panasonic KX-TA82483 - Expansion Cards Programming Manual

Advanced hybrid system
Table of Contents

Advertisement

2.
To avoid unauthorized access and possible fraudulent dialing, maintain the secrecy of the
password.
3.
We strongly recommend that you change the default password value to something else for reasons
of system security. It is best to use a password of 7 digits.
4.
Please change the password periodically.
5.
If a system password is forgotten, it can be found by loading a backup of the system data into a
PC, and checking the password using the KX-TA Maintenance Console software. If you do not have
a backup of the system data, you must reset the PBX to its factory defaults and reprogram it.
Therefore, we strongly recommend maintaining a backup of the system data. For more information
on how to back up the system data, refer to the on-line help that appears by selecting the Help
menu during PC programming. However, as system passwords can be extracted from backup
copies of the system data file, do not allow unauthorized access to these files.
Notes
This PBX has only one system password. It can be changed by either PT programming or PC
programming. For this reason, the password can consist of numerals only.
Programming Manual References
2.1 PT Programming—Instructions
3.2 PC Programming
Feature Manual References
1.1.99 PC Programming
1.1.103 PT Programming

[003] DSS Console Jack Assignment

Selects the number of the extension jack that the DSS Console is connected to.
0
0
3
Conditions
To delete (disable) an extension jack number, press CLEAR in the extension jack number step.
The same jack number cannot be assigned to 2 DSS Consoles.
Do not assign extension jack 01 (manager extension) as the DSS Console jack.
The extension jack number preassigned as a paired telephone in [004] Console Paired Telephone
should not be assigned in this program.
Programming Manual References
[004] Console Paired Telephone
Feature Manual References
1.1.54 Extension Jack Configuration
DSS console no.
NEXT
(1 ... 2)
2.2 PT Programming—Procedures
extension jack no.
STORE
(02 ... 24/
Disable)
To continue
NEXT
or
PREV
END
Programming Manual
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-ta824