10-16. Adjusting the work clamp lift amount

The maximum lift amount for the work clamp is 30 mm above the top of the needle plate.
5018Q
1. Turn on the air, and depress the work clamp switch (1) to raise the work clamp (2).
2. Loosen the two bolts (4) of the left and right work clamp arm levers (3), and then move the work clamp arm levers (3) up
or down to adjust.

10-17. Adjusting the air pressure

Lift up the handle (2) of the regulator (1) and then turn it to
adjust the air pressure to 0.5 MPa.
After adjustment is complete, push the handle (2) downward
to lock it.
4712M
BAS-300G-484, BAS-300G-484 SF
10. STANDARD ADJUSTMENTS
Max. 30mm