SW55 No. 4 ~ No. 8 Reserved
SW56 No. 1 ~ No. 4 Reserved
SW56 No. 5, No. 6 CNG detection time after ringing
CNG detection time after completion of ringing.
SW56 No. 7, No. 8 Reserved
SW57 No. 1 ~ No. 3 Reserved
SW57 No. 4, No. 5 Pop server access interval
Set the access interval to the Pop server.
SW58 No. 1 ~ No. 7 Reserved
SW58 No. 8 CED detection time
It is effective to change the CED auto detection time setting if detection
error often occurs.
SW59 No. 1 MH fixed
1: Both transmission and reception are forcibly fixed to MH.
0: Adjusted to the performance of the other party's machine.
SW59 No. 2 ~ No. 8 Reserved
SW60 No.1 ~ No. 8 Reserved
SW61 No. 1 ~ No. 8 Reserved
SW62 No. 1 Digital cable equalizer for transmission
Digital cable equalizer for transmission
0: OFF
1: ON
SW62 No. 2 ~ No. 8 Reserved
SW63 ~ SW76 No. 1 ~ No. 8 Reserved
SW77 No. 1 ~ No. 3 Reserved
SW77 No. 4 Error criterion
Used to select error criterion for sending back RTN when receiving
image data.
SW77 No. 5 Toner empty print
Used to specify whether or not to cancel printing when "Toner Empty"
is displayed.
SW77 No. 6 Reserved
SW77 No. 7 Drum life over
Used to set whether or not to cancel printing when "Drum life over" is
displayed.
SW77 No. 8 Reserved
SW78 ~ SW143 No. 1 ~ No. 8 Reserved
SW144 No. 1 ~ No. 3 Connect configuration for LAN controller
Used to set the communication speed when connecting to LAN.
SW144 No. 4 ~ No. 8 Reserved
SW145 No. 1 ~ No. 4 Detect time of LAN link ON
Used to change the link ON detection time setting when inserting the
LAN cable.
SW145 No. 5 ~ No. 8 Detect time of LAN link OFF
Used to change the link OFF detection time setting when inserting the
LAN cable.
SW146 No. 1 Reserved
SW146 No. 2, No. 3 Default resolution for network scan
Used to set the default resolution for network scan.
SW146 No. 4 ~ No. 8 Reserved
SW147 No. 1 ~ No. 8 Reserved
SW148 No. 1 ~ No. 4 DST start time-Month (1~12)
Used to set the start month of SW-41 No. 6 Summer time (Daylight
saving).
SW148 No. 5 ~ No.8 DST start time-Week
Used to set the start week of SW-41 No. 6 Summer time (Daylight sav-
ing).
SW149 No. 1 ~ No. 3 DST start time-Day of week
Used to set the start day of week of SW-41 No. 6 Summer time (Day-
light saving).
SW149 No. 4 ~ No. 8 DST start time-Hour
Used to set the start hour of SW-41 No. 6 Summer time (Daylight sav-
ing).
SW150 No. 1 ~ No. 4 DST end time-Month (1~12)
Used to set the end month of SW-41 No. 6 Summer time (Daylight
saving).
SW150 No. 5 ~ No. 8 DST end time-Week
Used to set the end week of SW-41 No. 6 Summer time (Daylight sav-
ing).
SW151 No. 1 ~ No. 3 DST end time-Day of week
Used to set the end day of week of SW-41 No. 6 Summer time (Day-
light saving).
SW151 No. 4 ~ No. 8 DST end time-Hour
Used to set the end hour of SW-41 No. 6 Summer time (Daylight sav-
ing).
SW152 No. 1 FTP mode set
Used to display the selection screen for FTP mode Passive/Active
when setting up an FTP client.
SW152 No. 2 User control
Used to enable the user control function.
SW152 No. 3 Authorized method
Select an authentication method when the user control function is
enabled.