LYNXR-I Installation and Setup Guide
System Operation
"Follow Me" Reminder Feature
This feature allows the user to schedule a time driven message. When activated the system will dial a phone
number, that the installer programs in Field
The LYNXR-I will immediately begin transmitting the voice message and will repeat the message for 45
seconds. Pressing any touch-tone key on the answering phone will acknowledge the message ending the
session and preventing the system from redialing the programmed number. Delivery of a reminder message
on the local LYNXR-I keypad will continue. If the message has timed out the system will redial the
programmed number a maximum of seven additional times or until it is acknowledged. Pressing any key on
the LYNXR-I keypad will terminate (acknowledge) both the follow me reminder and the local reminder
announcements.
Notes: (1) This feature is only supported if programmed in field ✻49.
(2) The follow me reminder will be terminated if any other event requires the system to dial out, or if an audible alarm has occurred,
however, delivery of the local schedule reminder message will continue.
"Follow Me" System Announcement Feature
This feature allows the LYNXR-I to deliver a voice system message to the secondary phone number
programmed by the installer. The LYNXR-I will first transmit reports to the Central Station and after
receiving its kiss-off the system will dial the secondary phone number and begin transmitting the voice
message. This message is a repeatable system status announcement. Like the Follow Me reminder, pressing
any key on the answering telephone or the local LYNXR-I keypad will terminate (acknowledge) the message.
The system will dial the secondary phone number a maximum of eight times. The Follow Me alarm
functions may be triggered by a variety of events depending upon the selections made during programming
in field
49.
Note: The follow me system announcement will be terminated if any other event requires the system to dial out or if an
audible alarm has occurred.
Powerline Carrier Devices (e.g. X10 devices)
If Powerline Carrier Devices are used, two keypad entries available to the user are included. They
can manually activate or deactivate the device(s) for starting or stopping some action, such as
turning lights on or off, etc.
These keypad entries are:
Security Code* + [#] + [4] + Device # activates (starts) that device.
Security Code* + [#] + [7] + Device # de-activates (stops) that device.
*Code is required for devices 7 and 8. Code is not required for devices 1-6.
Exit Error Alarm Displays
The system will display the following if programmed in Field *59.
Display
CA
will appear along with a zone indication if an exit or interior zone contained a
fault during closing at the time the exit delay ended (e.g., exit door left open),
but the system was disarmed during the entry delay time. The alarm
sounder and keypad sound continuously, but stop when the system is disarmed.
No message will be transmitted to the central station.
EA
will appear along with a zone indication if an exit or interior zone contained a
fault during closing at the time the exit delay ended, but the system was NOT
disarmed during the entry delay time. The alarm sounder and keypad
sound continuously until the system is disarmed (or timeout occurs). An Exit
Alarm message is sent to the central station. OR
if an alarm from an exit or interior zone occurs within two minutes after the
end of an exit delay
Entering a second OFF sequence (Code +
46, and deliver a voice message (custom words 72, 73, and 74).
Meaning
) will clear the display.
OFF
- 54 -