Honeywell WAVE2EX - Ademco Two Tone Siren Installation And Setup Manual page 23

Self-contained, rechargeable wireless control/communicators
Table of Contents

Advertisement

Split/Dual Reporting
49
To Primary
0 = All reports
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test
5 = All reports
To Primary
6 = All reports except Open/Close
7 = All reports
8 = All reports
9 = All reports except Open/Close
To Primary
10=All reports except Open/Close
11 = All reports
12=All reports
13=All reports except Open/Close
‡ Will report Users 0, 5-8, and, if using wireless button-type
devices, will report the zone number of the arm or disarm
button 26-33. All other zones and users are not reported.
15-Second Dialer Delay (Burglary)
50
0 = no dialer delay
1 = provide 15-second delay of burglary alarm report
when armed away
Periodic Test Report
51
0 = no test report
1 = once every 24 hrs
First test Report Offset
52
0 = 24 hrs after exit program mode or download
1 = 6 hours after exit program mode or download
2 = 12 hrs after exit program mode or download
3 = 18 hrs after exit program mode or download
Sescoa/Radionics Select
53
0 = Radionics (0–9, B–F reporting)
1 = SESCOA (0–9 only reporting)
Lack of Usage Notification
54
0 = Disabled
1 = 1 day
2 = 7 days
3 = 27 days
Note: There is no local annunciation indicating that this
report has been sent to the Central Station.
Enable/Disable LRR/IP Communications
55
Device
0 = disable
1 = enable
To Secondary
None, unless primary
fails, then all
Others
Open/Close, Test
All
All
All
To Paging Number
Alarms, Open/Close ‡ ,
Troubles
Alarms, Troubles
Alarms, Open/Close ‡ ,
Troubles
Open/Close ‡
To Follow Me System
Phone Number
Alarms, Open/Close ‡ ,
Troubles
Alarms, Troubles
Alarms, Open/Close ‡ ,
Troubles
Open/Close ‡
2 = weekly
3 = once every 30 days
4 = 90 days
5 = 180 days
6 = 365 days
- 23 -
LYNXR-I Installation and Setup Guide
Data Field Descriptions
This field is used to select a reporting option as follows:
Enter: 0 - 5 when reporting to telephone receivers.
6 - 9 when reporting to a pager is desired.
10 - 13 when reporting to an auxiliary telephone receiver.
Pager Report Format
Options 6-9 send reports to the primary phone number, in a
format defined in Field ✻ 48, and send reports to a pager, which
has its phone number entered as the secondary phone number in
Field ✻ 42. The pager report is a 7-digit code, with optional 16-
digit prefix, in the following format:
AAAAAAAAAAAAAAAA-EEE–0NNN where:
AAA = Optional 16 digits for PIN number, etc. See Field ✻ 88 for
full description of these characters.
EEE = 3-digit Event Code as follows:
911 = Alarm (NN = zone number)
101 = Open, system disarmed (NN = user no.)
102 = Close, system armed (NN = user no.)
811 = Trouble (NN = zone no.)
0 =
Always displayed before 3-digit user/zone no.
NNN = 3-digit user number or zone number, depending on the
type of event (EEE) that occurred.
Follow Me System Report Format
Options 10-13 send reports to the primary phone number, in a
format defined in Field ✻ 48, and sends voice message to the
secondary phone number entered in Field ✻ 42.
The message is a repeatable system status announcement. If the
manual paging option has been programmed in Field ✻ 87, the
message will repeat "system, system.....".
The message can be terminated by pressing any key on the
telephone keypad.
If enabled, provides delay of burglary report to the central station,
and allows time for the subscriber to avoid a false alarm
transmission. The delay applies only to zone type 3 and 5 alarms
and not to zone type 24 alarms (silent burglary) or to 24-hour zone
types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm),
which are always sent as soon as they occur.
UL installations: must be 0 (no delay)
Test report code entered in field ✻ 64 is sent.
Select the time for the first report following programming or
downloading.
If disabled, selects Radionics, which uses hexadecimal 0-9, B-F
reporting.
If enabled, selects Sescoa, which uses only numeric reporting (0-9).
Select 0 for all other formats.
If enabled, notifies the central station if an end user is not
operating their security system by sending a System Inactivity
report 654. The report will be sent only to the Primary phone
number and only if Contact ID® format was selected.
Note: The report will follow the ✻ 49 = 0 rules, no matter which
selection was made in ✻ 49.
This option is used to enable/disable Central Station reporting via
the LRR/IP Communications Device (See Field *77). Upload/
download via the Internet IP module is not affected by this entry.
Zone 103 supports the LRR/IP Communications Device.
Notes: (1) When LYNXR-I is in programming mode it will not
communicate with the LRR/IP device. As a result the
LRR/IP device will transmit 355 (event and restore)
reports to the Central Station.
(2) Zone 103 can not be bypassed.