LYNXR-I Installation and Setup Guide
Data Field Descriptions
RF Jam Detection
58
0 = no jam detection
1 = RF jam detection with event logging, but no
central station report
2 = RF jam detection with event logging and with
central station report (if trouble/restore report is
enabled in fields ✻60, ✻71)
SYSTEM STATUS AND RESTORE REPORT CODES PROGRAMMING ( ✻ 59 – ✻ 76, & ✻ 89)
Program Report Codes using the interactive ✻ 56 Enhanced Zone Programming Mode, or codes can be entered in data
fields ✻ 59- ✻ 76, ✻ 89. The following is a set of guidelines when programming report codes. The actual report code digits
that you enter depend upon the particular installation, and should be in agreement with you and the central station
office receiving the signals.
With a 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, A, B, C, D, E, or F. Enter "#+10" for A
(reports a "0" on some receivers), "#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F. Entering "0" in the
first box will disable a report. Entering "0" in the second box results in automatic advance to the next field.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, or A–F, as described above.
Entering "0" in the first box will disable a report. Entering "0" in the second box will eliminate the expanded message for
that report.
With ADEMCO Contact ID® Reporting: Enter a digit in the first box to enable the zone to report. Use a different
digit for each zone until you have used up available digits. If the number of zones exceeds the number of available
digits, begin with digit 1 again. This is an "enabling" code only and is not the actual code sent to the central station
office. Entries in the second boxes will be ignored. For system status (non-alarm) codes, enter a "1" in the first box for all
the system conditions you want to send to the central station. A "0" in the first box disables the report.
SYSTEM STATUS REPORT CODES (
Exit Error Report Code
59
(See notes above)
Trouble Report Code
60
(See notes above)
Bypass Report Code
61
(See notes above)
AC Loss Report Code
62
(See notes above)
For Event Logging, Option 2 must be selected.
If the control detects an RF Jam condition, a "FAULT" message
appears for zone 90. The Contact ID® code for RF Jam is 344.
59–
68)
If the system is armed and an entry/exit or interior zone is still
open after the exit delay time has expired, an alarm will sound
at the keypad and external sounder. If the system is disarmed
before the end of the entry delay that immediately follows, the
alarm sounding will stop and no message will be sent to the
central station. The keypad will display "CA (CANCELED
ALARM)."
If the system is not disarmed before the end of the entry delay
mentioned above, and an entry/exit or interior zone is still open,
an "exit alarm" message will be sent to the central station if an
Exit Error report code is selected in this field. The keypad will
display "EA (EXIT ALARM)," and the alarm sounding will
continue until the system is disarmed (or timeout occurs).
An Exit Alarm condition will also result if a fault occurs in an
exit or interior zone within 2 minutes following the end of the
exit delay, and an "Exit Alarm" message will be sent to the
central station.
If Contact ID® format has been programmed, the message will
contain the zone number and error code 374 (Trouble–Exit
Error). If 4+2 format is used, the digit entered in this field will
be sent followed by the second digit of the programmed alarm
code for that zone. If 3+1 or 4+1 format is used, only the digit
entered in this field will be sent. This message will go to the
primary phone no. Under any of these conditions, no restore
message will be sent.
If "0" is entered in this field, no special message will be sent,
only the regular alarm and alarm restore code for the zone.
This will be sent if a zone goes into trouble.
This will be sent when a zone is manually bypassed.
Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no AC restore report.