Configuring Power over Ethernet Parameters

Power over Ethernet Defaults

The following table lists the defaults for PoE configuration:
Parameter Description
PoE operational status
Total power allocated to a port
Total power allocated to an
entire OS6600-P24 chassis
Power priority level for a port
The capacitor detection method
Priority disconnect status

Understanding and Modifying the Default Settings

The sections below provide information on each of the key components within the Power over Ethernet
software. They include information on PoE-related CLI commands. For detailed information on PoE-
related commands, refer to the OmniSwitch CLI Reference Guide.

Setting the PoE Operational Status

Enabling PoE
By default, Power over Ethernet is administratively enabled in the switch's system software. However, in
order to physically activate PoE, you must issue the
before any connected PDs will receive inline power.
To activate power to PoE-capable ports in a switch, enter the corresponding slot number only. For exam-
ple:
-> lanpower start 3
Note. You cannot activate PoE for more than one switch in a stack at a time. Also, an OmniSwitch 6600-
P24 must have the corresponding slot number.
If power to a particular port has been disconnected via the
power to the port by specifying both the slot and port in the command line. For example:
-> lanpower start 3/11
Note. You cannot use the slot/port syntax to initially activate PoE on a port. This syntax is intended only
to reactivate power to those ports that have been disconnected via the
initially activate PoE, you must use the lanpower start slot syntax only, as described above.
OmniSwitch 6600 Family Hardware Users Guide
Command(s)
lanpower start
or
lanpower stop
lanpower power
lanpower maxpower
lanpower priority
lanpower capacitor-detection
lanpower priority-disconnect
lanpower start
lanpower stop
September 2006
Configuring Power over Ethernet Parameters
Default Value/Comments
Disabled
15.4 Watts
210 Watts
low
Disabled
Enabled
command on a slot-by-slot basis
command, you can reactivate
lanpower stop
command. To
page 3-5