Super G3 mode
Error Code
Transmission Errors
E-16
Same as E-0
E-17
Same as E-1
E-18
Same as E-2
E-19
E-20
Same as E-4
E-21
E-22
E-23
Same as E-7
E-24
Same as E-8
E-25
Same as E-11
E-26
Same as E-12
E-27
Same as E-13
E-28
E-29
E-30
Error occured during handshaking for super G3 mode
E-31
<Reference> Details of E-29 ~ 31
E-29
Handshaking error in V.8 negotiation procedure
E-30
Handshaking error in V.34 line probing procedure
E-31
Handshaking error in V.34 HDX training procedure
2. Service call error massage
The following service call errors may occur in FO-2970MU.
Message
1
POLYGON ERROR
2
HEATER ERROR
3
HEATER HIGH ERROR
4
HEATER LOW ERROR
Only the power on and off can be restored when the service error occurs.
Reception Errors
Same as E-0
Same as E-1
Same as E-2
Same as E-8
Same as E-9
Same as E-10
Same as E-7
Same as E-11
Same as E-12
Same as E-13
Same as E-14
Cause: When the recognition of the laser beam detection signal (HSYNC) is impossible after the printing is
started.
[HSYNC interruption is usually done once every 846.7 S for PC printing and once every 1298.7524 S for
other printing (copying, reception and list).]
Cause: When the disconnection of the thermistor is counted 8 times (80ms).
Cause: When the temperature of the heater lamp exceeds 188 C during 200 ms.
Cause: When the temperature does not exceed 97 C within 15 seconds after the heater lump is ON, or it is
less than 97 C even while printing.
2 – 29