13.2 Errata; Intel® Raid Controller Srcmr Not Yet Supported With Intel® Server Board Sds2; Intel® Server Board Sds2 Bios Update Utility Does Not Allow Updates From A Pxe Server Or From Network Drives; Intel® Server Board Sds2 Fru/Sdr Update Fails With Console Redirection Enabled In Bios Setup - Intel SDS2 Specification

Product specification
Hide thumbs Also See for SDS2:
Table of Contents

Advertisement

Errata Listing

13.2 Errata

[DD1]
1.
Intel® RAID controller SRCMR not yet supported with Intel®
Server Board SDS2
Problem:
The Intel RAID Controller SRCMR installed on the Intel Server Board SDS2 is
currently an unsupported configuration. Intel has induced a failure condition in
Intel Server Board SDS2 systems configured with the Intel RAID Controller
SRCMR under extreme workloads during final validation testing. Intel has
verfied that other Intel RAID controllers and Intel server boards are not affected
by this issue. The Intel RAID controller SRCMR installed on the Intel Server
Board SCB2 does not exhibit this failure.
Implication:
The Intel RAID Controller SRCMR installed on the Intel Server Board SDS2 is
currently not a supported configuration and should not be implemented in a
production environment. .
Workaround:
None.
Status:
Will not fix .
2.
Intel® Server Board SDS2 BIOS update utility does not allow
updates from a PXE Server or from network drives
Problem:
The current Intel Server Board SDS2 BIOS update utility (PhoenixPhlash) does
not allow the BIOS updates to be performed from a PXE server or from a
network drive.
Implication:
The Intel Server Board SDS2 BIOS cannot be updated from a PXE server or a
network drive. The BIOS update must be performed from a floppy diskette or
from a hard drive.
Workaround:
None.
Status:
Fixed. SDS2 BIOS Production Release 2.1 (Build 44) adds support for the Intel
iFLASH BIOS update utility. The iFLASH BIOS update utility has the ability to
perform BIOS updates from a PXE server or from network drives.
3.
Intel® Server Board SDS2 FRU/SDR update fails with console
redirection enabled in BIOS Setup
Problem:
When using Intel Server Board SDS2 BIOS Production Release 2 (Build 41),
BMC v. 28, and FRU/SDR files v. 5.0.A, if console redirection is set to Enabled
108