System Switches
System Switches Default Settings
CPU Frequency (MHz)
350
400
450
500
550
Must Be OFF (7 & 8)
On = Clear Password (6)
On = Clear Config (5)

Specifications

Temperature
Operating
Non-operating
Humidity (non-condensing)
Operating
Non-operating
Altitude
Operating
Non-operating
Thermal Output
Maximum Operating
Minimum Clearance
Weight and Dimensions
Weight
Width
Depth
Height
Power Supply Specifications
Type
Input - Max.
Range
Operating Current
In-rush Current
Operating Power
10
5 to 35 C (41 to 95 F)
-40° to +65° C (-40° to +149° F)
20% to 80% relative humidity, non-condensing
5% to 95% relative humidity, non-condensing
-30 to 3,000 m (~ 10,000 ft)
-30 to 12,000 m (~ 40,000 ft)
1041 BTU/hr
No requirement in HP racks.
Approx. 40 lbs (88 kg)., depending on configuration
17.6 inches (44.7 cm)
28 inches (71.1cm)
3.5 inches (8.9 cm)
Auto-ranging
88 to 140 VAC at 47 - 63 Hz
100 VAC: 5.3
120 VAC: 4.6 A
200/208 VAC: 3.2 A
220/230 VAC: 2.8 A
25 A
305 W