Cr_Filh Command; Cr_Filtimer Command; Cr_Filcond Command; Cr_Filrepl Command - Sanyo PLC-WM5500/L - 5500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WM5500/L - 5500 Lumens:
Table of Contents

Advertisement

PLC-WM5500/WM5500L Expand Serial Command Functional Specifications

9.11.17 CR_FILH Command

Command
"CR_FILH" [CR]
Details
Get Filter used time
Acceptable
Response
%1
Unacceptable

9.11.18 CR_FILTIMER Command

Command
"CR_FILTIMER" [CR]
Details
Get Filter used time
Acceptable
Response
%1
Unacceptable

9.11.19 CR_FILCOND Command

Command
"CR_FILCOND" [CR]
Details
Get status of filter clog
Acceptable
Response
%1
Unacceptable

9.11.20 CR_FILREPL Command

Command
"CR_FILREPL" [CR]
Details
Get status of Filter cleaning / replacement time
Acceptable
Response
%1
Unacceptable

9.11.21 CR_FANSPEED Command

Command
"CR_FANSPEED" [CR]
Details
Get selected Fan Control Speed mode.
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"00000 - 99999"
"Error Code" [CR]
"000_%1" [CR]
"0400" ---------------------- Display massage by 400h used.
"0700" ---------------------- Display massage by 700h used.
"1000" ---------------------- Display massage by 1000h used.
"OFF" ---------------------- Off(Warning display is not displayed)
"Error Code" [CR]
"000_%1" [CR]
"CLOG" = Filter is clogged
"WARN" = Filter is nearly clogged
"CLEAN" = Filter is not clogged
"Error Code" [CR]
"000_%1" [CR]
"1Y"-------Filter Exchange time is over value of Filter Message.
"1N"--Filter Exchange time is not over value of Filter Message.
"Error Code" [CR]
"000_%1" [CR]
"MAX" ------------------------ Max mode is selected
"NOR" ------------------------ Normal mode is selected
"Error Code" [CR]