PLC-XW200/250/300
Expand Serial Command Functional Specifications
9.7 Input Status Read Command
9.7.1
CR_INPUT Command
Command
"CR_INPUT"[CR]
Details
Get selected INPUT No.
Acceptable
Response
Request data
Unacceptable
9.7.2
CR_SOURCE Command
Command
"CR_SOURCE"[CR]
Details
Get selected Source
Acceptable
Response
Request data
Unacceptable
9.7.3
CR_SRCINP1 Command
Command
"CR_SRCINP1" [CR]
Details
Get selected source of Input 1_CMP1
Acceptable
Response
Request data
Unacceptable
9.7.4
CR_SRCINP2 Command
Command
"CR_SRCINP2" [CR]
Details
Get selected source of Input 2_CMP2
Acceptable
Response
Request data
Unacceptable
9.7.5
CR_SRCINP3 Command
Command
"CR_SRCINP3" [CR]
Details
Get selected source of Input 3_Video
Acceptable
Response
Request data
Unacceptable
"000_%1"[CR]
"1"-"3"
"Error Code"[CR]
"000_%1"[CR]
"ANALOG" ---------- Analog (RGB) Input is selected
"SCART" ------------- SCART is selected
"VIDEO" -------------- Video Input is selected
"S-VIDEO" ----------- S-Video Input is selected
"YPBPR" ------------- Component Input is selected
"Error Code"[CR]
"000_%1"[CR]
"ANALOG" ---------- Analog RGB Input is selected
"YPBPR" ----------- YPBPR Input is selected
"S-VIDEO" ----------- S-Video Input is selected
"SCART" ----------- Scart Input is selected
"Error Code"[CR]
"000_%1"[CR]
"ANALOG" --------- Analog RGB Input is selected
"OUT" ---------------- Monitor out 0nr¶ a K
"Error Code"[CR]
"000_%1"[CR]
"VIDEO" ------------- Composite Video Input is selected
"Error Code"[CR]
47 / 64