Brocade DCX-4S Backbone Hardware Reference Manual
In this chapter
The updates in this chapter are for various hardware manuals.
Chapter 5, Removal and Replacement Procedures
All of the following occurs under the heading "Removal and replacement of the WWN card."
Under the subheading "Determining the status of a WWN card" on page 68, replace the
information in Table 11 in the Sample error message column for the WWN unit is being faulted row
with the following information:
Before the subheading "Removing the WWN card and WWN bezel (logo plate)" on page 69, add the
following section:
Preparing for the WWN card replacement
If the WWN card requires replacement, complete the following steps.
ATTENTION
Follow ESD precautions (see "ESD Precautions" in your chassis manual).
1. Open a Telnet session to the chassis and log in to the active CP as admin. The default
2. Verify that you are logged into the active CP. Run the haShow command to determine the active
3. Run the supportsave command on the active CP to capture all settings.
Fabric OS Documentation Updates
53-1002165-05
•
Chapter 5, Removal and Replacement Procedures . . . . . . . . . . . . . . . . . . . 49
Type of message
WWN unit is being faulted.
password is "password".
CP.
Sample error message
<timestamp>, [EM-1034], <sequence-number>,,
ERROR,
<system-name>, WWN # set to faulty, rc=<return
code>
or
<timestamp>, [EM-1003], 40, SLOT 7 | FFDC |
CHASSIS, CRITICAL, Brocade_DCX, WWN 2 has unknown
hardware identifier: FRU faulted
Chapter
19
49