Fabric OS Command Reference
In this chapter
Documentation Updates for Fabric OS v7.0.1
The updates in this section are for the Fabric OS Command Reference, publication number
53-1002447-01, published December 15, 2011.
The note on page xxi in the Preface includes an incorrect platform reference. The note should read:
portCfgOctetSpeedCombo - Not supported on the Brocade 6505; supported on the Brocade FC8-32E
and FC8-48E port blades only with the default combination.
portCfgDPort
Add the following configuration option to the portCfgDport --enable command:
portcfgdport --enable [slot/]port_list dwdm
D_Port functionality is only available on 16Gbit-capable platforms with 16Gb SFPs and 10Gb FC SFPs.
portCfgShow
On page 688, add the following descriptions under the "Non-GbE port displays" section:
Octet Speed Combo: Displays the current octet speed combo setting. This parameter is set by the
D-Port over DWDM
portStatsShow
This command has been updated to include the following counters. These counters are supported only
on Condor3-based platforms and display only on these platforms
er_single_credit_loss
Fabric OS Documentation Updates
53-1002165-05
•
Documentation Updates for Fabric OS v7.0.1 . . . . . . . . . . . . . . . . . . . . . . . . . 7
•
Documentation Updates for Fabric OS v7.0.0 . . . . . . . . . . . . . . . . . . . . . . . . . 9
Skips the optical loopback test when you run the D_Port diagnostics over a Dense
Wavelength Division Multiplexing (DWDM) link or any third party equipment that
connects two switches.
portCfgOctetSpeed command. In unsupported platforms, this display is not
shown
Displays ON when the D_P ort is configured over a DWDM link. This parameter is
set by portCfgDPort command and displays only if portcfgDPort is configured
with the dwdm option.
Chapter
4
7