Chapter 4, Fe Mib Objects - Brocade Communications Systems SN3000B Documentation Update

Brocade fabric os documentation updates - supporting fabric os v7.0.x (53-1002165-05, march 2012)
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

11
Documentation updates for Fabric OS v7.0.1

Chapter 4, FE MIB Objects

Under the heading "Definitions for FIBRE-CHANNEL-FE-MIB" on page 75, replace the following rows
in Table 9.
TABLE 9
Type Definition
FcFeFxPortCapacity
fcfeModuleFxPortCapacity
Under the MIB object "fcFeModuleFxPortCapacity 1.3.6.1.2.1.75.1.1.4.1.6" on page 77, add the
following to the existing list:
Brocade 6505
Brocade VA-40FC
Under the MIB object "entPhysicalClass 1.3.6.1.2.1.47.1.1.1.1.5" on page 109, add the following
information:
Brocade 6505 switch can have the following hierarchy of physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two power supplies, two fans)
Module: One entry for switch blade, up to two entries for power supplies, and up to two entries
for fans.
Brocade VA-40FC switch can have the following hierarchy of physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one blade, two power supplies, two fans)
Module: One entry for blades, two entries for power supplies, and two entries for fans
28
DRAFT: BROCADE CONFIDENTIAL
FIBRE-CHANNEL-FE-MIB definitions
Value
Integer from 1 to 640
Integer from 1 to 640
24 ports
40 ports
Description
Maximum number of Fx_Ports within a module.
For the Brocade 300, this value is 24.
For the Brocade 4100, this value is 32.
For the Brocade 4900, this value is 64.
For the Brocade 5000, this value is 32.
For the Brocade 5100, this value is 40.
For the Brocade 5300, this value is 80.
For the Brocade 7500 or 7500E, this value is 32.
For the Brocade 7600, this value is 16.
For the Brocade 7800 Extension Switch, this value is 24.
For the Brocade 8000, this value is 32.
For the Brocade Encryption switch, this value is 32.
For the Brocade DCX, this value is 640.
For the Brocade DCX-4S, this value is 320.
For the Brocade 48000, this value is 384.
For the Brocade 6510, this value is 48.
For the Brocade DCX 8510-4 Backbone, this value is 320.
For the Brocade DCX 8510-8 Backbone, this value is 640.
For the Brocade 6505, this value is 24.
For the Brocade VA-40FC, this value is 40.
Maximum number of Fx_Ports within a module.
Fabric OS Documentation Updates
53-1002165-05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 8/12cBrocade 8/24cFabric os 7.0

Table of Contents