The nonport side of the switch has one LED per power supply/fan assembly. See
37). The standard configuration of the HP SN3000B 16Gb FC Switch includes a single power
supply/fan assembly.
Figure 17 Power supply/fan status LEDs
1. Power supply/fan assembly status LED
Table 6 Nonport side LED patterns
LED name
Power
supply/fan
assembly status

POST and boot specifications

When the switch is powered on or rebooted, it performs POST. Total boot time with POST can be
several minutes. POST can be omitted after subsequent reboots by using the fastboot command
or entering the diagDisablePost command to persistently disable POST. For more information
about these commands, see the Fabric OS 7.0.x Command Reference Manual.

POST

You can monitor the results of the diagnostic tests that run during POST through LED activity, the
error log, or the CLI. POST includes the following tasks:
Conducting preliminary POST diagnostics
Initializing the operating system
Initializing hardware
Running diagnostic tests on several functions, including circuitry, port functionality, memory,
statistics counters, and serialization
To determine whether POST completed successfully:
1.
Inspect the switch LEDs to determine whether components are operating properly.
See
Table 5 (page 36)
LEDs do not display a healthy state, verify that the LEDs are not set to beacon by entering the
switchshow command to detect if beaconing is active.
Table 6 (page 37)
LED color
Status of hardware
No light
Power supply/fan is not receiving
power or is off.
Steady green
Power supply/fan is operating
normally.
Flashing green
Power supply/fan is faulty.
When the switch is first powered on
the power supply/fan status LED is
flashing green until POST is
complete.
and
Table 6 (page 37)
describes the status.
Recommended action
Verify the power supply/fan is on and
seated and the power cord is connected to
a functioning power source.
No action required.
Check the power cable connection. Verify
that the power supply/fan is powered on.
Replace the power supply/fan FRU.
for descriptions of LED patterns. If one or more
Figure 17 (page
POST and boot specifications
37