Removing and Replacing the Side Access Panel and
Metal Side Cover

Removing the Side Access Panel and Metal Side Cover

WARNING!
power cord is disconnected from the electrical outlet.
To remove the access panel:
1.
Remove the secure USB compartment cover (1). For more information, see
Secure USB Compartment Cover on page
2.
Remove the stand, if it is installed (2). See
3.
Lay the thin client on its side on a secure working surface.
Remove the right side access panel if you are removing or installing:
Remove the left side access panel if you are removing or installing a second SO-DIMM.
4.
Slide the access panel about 6.35 mm (1/4 inch) toward the top of the unit (3), and then lift the
access panel up and off the unit (4).
Figure 2-3
To remove the metal side cover:
NOTE:
Do not remove the metal side cover when installing a PCI Expansion Module or a second
SO-DIMM.
You must remove the metal side cover to access internal components such as the battery or the
memory.
1.
Remove the four screws that secure the metal side cover to the chassis (1).
14
Chapter 2 Hardware Changes
Before removing the side access panel, ensure that the thin client is turned off and the
battery
secondary flash memory module
PCI expansion module and PCI card
Removing the side access panel
12.
Removing the Stand on page 6
Removing the
for more information.