A-Class System Service
A-Class Server RAM Removal and Replacement
A-Class Server RAM Removal and Replacement
Overview
This section provides step-by-step instructions and general installation rules for
removing and replacing RAM boards in the A-Class Server. The following subsections
apply:
•
•
•
CAUTION
The procedures in this section require opening the system cabinet and exposing the
system to electrostatic discharge. Always observe all electrostatic precautions when
working with components inside or out of the cabinet. Failure to follow these precautions
may result in component damage or loss of system reliability.
Electrostatic Discharge Precautions
•
•
Before You Do Anything...
Step 1. Perform system backup.
Step 2. Shut down the operating system.
Step 3. Power down the system.
Step 4. Unplug the server.
NOTE
Cabinet-mounted servers must be removed from the cabinet before proceeding.
Step 5. Remove the top of the server by unscrewing the knurled captive screws on each side of
the rear of the server. Slide the top back, lift it off, and set it aside.
84
RAM Removal
RAM Replacement
RAM Removal and Replacement Rules
Use a grounding mat and an anti-static wrist strap.
Wear the anti-static wrist strap to ensure that any accumulated electrostatic charge
is discharged from your body to ground.
Chapter 3