HP Rp2430 - Server - 650 MHz User Manual page 75

Rp24xx a180 user manual
Hide thumbs Also See for Rp2430 - Server - 650 MHz:
Table of Contents

Advertisement

<Press any key to continue (q to quit)> q
Service Menu: Enter command >
If a fault prevents the server from completing selftest, the OSTAT FLT is used and the
Chassis Code displays the test number that failed. If the server stops responding while
performing a test, the OSTAT value will be INIT or TEST and the chassis code
represents the test that was running when the server failed.
Refer to the table below to determine which tests were active when the system either
faulted or stopped responding during selftest, and the corrective action to take in
response to the problem.
Category
1xxx
2xxx
3xxx
4xxx
5xxx
6xxx
7xxx
8xxx
Chapter 3
INIT C4CC
INIT C4CD
INIT 3002
TEST 30BC
INIT 30BC
INIT C300
TEST 1030
OSTAT values of TEST and INIT are common during selftest.
OSTAT values of RUN and SHUT are common when the HP-UX operating system is
running.
OSTAT values FLT, OFF, and WARN are used to indicate when the server firmware
has failed a test or detected a problem that does not keep selftest from finishing.
Major
Code
Description
CPU/TLB Tests
SLC Tests
PDH Tests
Late Selftest
Bus Transactions
Unused
Memory Tests
I/O Device Codes
A-Class System Service
A-Class Server Trouble Shooting
Corrective Action
Refer to Replacing an A-Class Server Exchange
Base Unit (EBU)
Refer to Second Level Cache Memory Module
Fault.
Refer to Replacing an A-Class Server Exchange
Base Unit (EBU)
Refer to Replacing an A-Class Server Exchange
Base Unit (EBU)
Refer to I/O Subsystem or I/O Board Fault
NA
Refer to Second Level Cache/RAM Memory
Module Faults
Refer to I/O Subsystem or I/O Board Fault
75