Password Recovery [Option 3]; Enter Diagnostic Mode [Option 4]; Set Terminal Baud-Rate [Option 5] - HP BladeSystem bc2000 - Blade PC Installation Manual

Bladesystem pc blade switch
Hide thumbs Also See for BladeSystem bc2000 - Blade PC:
Table of Contents

Advertisement

The following message is displayed.
Write Flash file name (Up to 8 characters, Enter for none.): config
File config (if present) will be erased after system initialization
======== Press Enter To Continue ========
4.
Enter config as the name of the flash file.
The configuration is erased and the PC Blade Switch reboots.
5.
Repeat the initial PC Blade Switch configuration.

Password Recovery [Option 3]

If a password is lost, you can perform the password recovery procedure from the Startup menu. The
password recovery procedure enables entry to the PC Blade Switch one time without a password.
To recover a lost password for the local terminal only:
From the Startup menu, type 3 and press Enter.
The password is deleted.
NOTE:
To ensure security, reconfigure passwords for all applicable management methods.

Enter Diagnostic Mode [Option 4]

For Technical Support only.

Set Terminal Baud-Rate [Option 5]

To set the terminal baud-rate:
1.
From the Startup menu, type 5 and press Enter.
2.
Enter your choice or press
3.
Press Enter.
The baud-rate is set.
WARNING!
Administrator's internal serial link to the PC Blade Switch. To do so, while logged into the PC Blade
Switch via the IA console, press
Remote Port [Switch A]. From there you can adjust the Baud Rate and Flow Control. Note: As the default
baud rate is set to 115200, there should be no reason to ever have to change these settings.
ENWW
Esc
to exit.
If you change the terminal baud-rate, you must match these settings for the Integrated
Ctrl
+
Shift
+
_
then press
C
to Change Settings, then press
Startup Menu Procedures
R
for
27