To configure SNMP station IP address and community string(s), perform the following:
1.
At the console prompt, type Enable.
The prompt is displayed as #.
2.
Type configure and press Enter.
3.
In configuration mode, type the SNMP configuration command with the parameters including
community name (private), community access right (read and write) and IP address, as shown in
the following example:
console> enable
console# configure
config(config)# snmp-server community private rw 192.168.1.2
config(config)# exit
console(config)# show snmp
Community-String
-------------------
private
Community-String
Traps are enabled.
Authentication-failure trap is
enabled.
Version 1,2 notifications
Target address____ Type
----------------_____-----
Version 3 notifications
Target address___Type
Level
----------------____---------
SystemContact:
System Location:
ENWW
Community-Access
-------------------
readWrite
Group name
Community___ ____Version
___port_____name
------------_____------
Username_______Security
____port_______name
------------_______------
View Name
default
IP address
Udp_____Filter
sec
----_______-----
Udp_____Filter
sec
----_______-----
Configuration Overview
IP address
-------------------
192.168.1.2
Type
To_____Retries
--______--------
To_____Retries
--_______--------