2.3 Connections

2.3.1 Power supply

Electronic ballast with:
~90 - 260 Volt, 50 - 60 Hz, earth contact type plug - Powercon
Connected load 780W <=> 3.8 A (blind current compensation).
Please see printing on the case for the right electronic supply!

2.3.2 DMX

DMX 512 Standard input/output. See also printing on the case for the right
pin assignment.
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1
The DMX- Addressing starts at the DMX- Address [001].

2.4 Fuse

POWER WASH 575E
The POWER WASH 575E
wire fuses.
Lamp: 230V / T 5A
Electronic: 230V / T 1A
Please see the printing on the POWER WASH 575E
Attention:
• Disconnect AC outlet before changing a fuse!
• Use only the original declared fuse type!
Elation Lighting
electronic system is protected by two 5x20 mm fine-
POWER WASH 575E
www.elationlighting.com
casing for more details.