060. GAIN PARAMETER REQUEST 2
**********************************************************************
Function:
This command acquires the adjustment values.
Command:
03H 04H 00H 00H 03H DATA01 .. DATA03 CKS
Data Portion
Contents
-------------------------------------------------------------------
DATA01 .. 02
Acquirement items (!)
DATA03
00H fixed
Response: At the time of a success
23H 04H 01H xxH 0DH DATA01 .. DATA13 CKS
(*1) (*2)
Data Portion
Contents
-------------------------------------------------------------------
DATA01
Adjustment status
00H : Displaying impossible
01H : Adjustment impossible
02H : Adjustment possible
FFH : Selected gain is not available.
DATA02
Maximum adjustment value (Lower ranking 8 bits)
DATA03
Maximum adjustment value (Upper ranking 8 bits)
DATA04
Minimum adjustment value (Lower ranking 8 bits)
DATA05
Minimum adjustment value (Upper ranking 8 bits)
DATA06
Default adjustment value (Lower ranking 8 bits)
DATA07
Default adjustment value (Upper ranking 8 bits)
DATA08
Current value (Lower ranking 8 bits)
DATA09
Current value (Upper ranking 8 bits)
DATA10 .. 13 Reserved
Response: At the time of a failure
A3H 04H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2)
(*3)
(*3)
(*4)