037-7. LAMP INFORMATION REQUEST 4
**********************************************************************
Function:
This command acquires the information on the projector lamp.
Command:
03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS
Data Portion
Contents
-----------------------------------------------------------------
DATA01
Target
00H : Lamp1
01H : Lamp2
DATA02
Unit(!4)
00H : Second
01H : Reserved
02H : Hour
DATA03
Item
00H : Lamp Hour Meter (second)(!2)
01H : Lamp usage time (second)(!3)
04H : lamp remaining amount until lamp warning message
( 100% to -X%(!1) )
05H : Lamp usage time (Normal mode)(second) (!5)
06H : Lamp usage time (Eco mode)(second) (!5)
08H : Remaining time until lamp warning message starts
to appear (in terms of specified values)
09H : Remaining time until lamp warning message starts
to appear (in terms of Normal mode values)
0AH : Remaining time until lamp warning message starts
to appear (in terms of Eco mode values)
10H : Remaining time until inhibition of lamp usage
(in terms of specified values)
11H : Remaining time until inhibition of lamp usage
(in terms of Normal mode values)
12H : Remaining time until inhibition of lamp usage
(in terms of Eco mode values)
Response: At the time of a success
23H 9BH 01H xxH 07H DATA01 to DATA07 CKS
(*1) (*2)
Data Portion
Contents
-----------------------------------------------------------------
DATA01
same values as DATA01 of the command
DATA02
same values as DATA02 of the command
DATA03
same values as DATA03 of the command
DATA04 to 07
Acquired information
Response: At the time of a failure
A3H 9BH 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2)
(*4)
Supplement:
* In case of acquiring lamp's use of hours
03H 9BH 00H 00H 03H 00H 00H 01H CKS
Example of acquisition
DATA04 DATA05 DATA06 DATA07 : lamp's use of hours
50H
46H
00H
Lamp Usage = 18000 / 3600 = 5 hour
(*3)
(*3)
(*3)
00H
: 18000 seconds

Advertisement