Lenovo ThinkServer RD240 Hardware Maintenance Manual page 92

Hardware maintenance manual
Hide thumbs Also See for ThinkServer RD240:
Table of Contents

Advertisement

CAUTION:
The heat sink might be very hot. Turn off the server and wait three to five minutes to let the
server cool before removing the server cover.
To install the heat sink, do the following:
Note: Make sure that you have already connected the front fans to the system board before you install
the heat sink.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See Removing the server cover.
3. Notice the orientation of the heat sink air flow and the V-shaped cooling pipe. The V-shaped cooling
pipe should always face the power supply assembly. Then, align the retaining screws on the heat sink
with the corresponding holes in the system board. Install the four screws following the numerical
sequence as shown below (
Figure 56. Installing the heat sink
1
4
-
Screws
5
Air flow
6
The front of the chassis
4. To complete the installation, go to Completing the parts replacement.