Meter Window
The Meter window displays the Input, Output, Effect, and Stereo Out meters. To open the Meter win-
dow, choose [Meter] from the [Windows] menu. This window consists of four display pages. You can
access these pages by clicking the tabs along the top of the window.
Page
CH1-32 page
ST IN page
MASTER page
Effects 1-4 page
Stereo page
The layout of the Meter window pages is the same regardless of the page selected. (The Master page is
shown below.)
A
Meter mode
You can select the type of meters to be displayed from the following options:
GATE GR:
COMP GR: The meters indicate the amount of gain reduction being applied by the channel
LEVEL:
B
POSITION parameter
This parameter, available only when Meter mode is set to Level, enables you to select the metering
position in the signal path.
C
PEAK HOLD button
This button turns the Peak Hold function on and off.
This page displays the Input Channel CH1-32 meters (12 segments).
This page displays the Stereo Input Channel 1-4 meters (12 segments)
This page displays the Bus 1-8, Aux 1-8, and Stereo meters (12 segments).
This page displays the Channel 1 & 2 input/output meters (12 segments) for Effects
1-4.
This page displays a bar graph (32 segments) of signal levels output to the Stereo Out.
A
The meters indicate the amount of gain reduction being applied by the channel Gate.
Compressor.
The meters indicate the channel level.
Function
2
3
01V96 Editor—Owner's Manual