Brother BAS-342G PS Instruction Manual page 79

Direct drive programmable electronic pattern sewer, "perfect stitch"
Hide thumbs Also See for BAS-342G PS:
Table of Contents

Advertisement

Data editing-related errors
Code
The enlargement ratio setting caused the sewing data to extend outside the sewing area.
E500
Set the enlargement ratio again.
Sewing data that exceeds the sewing machine's sewing area was loaded.
E501
Check the size of the sewing data.
The enlargement ratio caused the data pitch to exceed the maximum pitch of 12.7 mm.
E502
Set the enlargement ratio again.
Invalid code in sewing data.
E510
Reload the data from the CF card or floppy disk.
No end code has been input into sewing data.
E511
Input an end code, or change the program number.
E512
Number of stitches exceeds allowed maximum.
Extended option output number already exists. Change the extended option output number.
E520
If not using the extended option output, initialize the data to clear the extended option output data.
E530
Changing program number is prohibited.
P.C. board-related errors
Code
Abnormal rise in power supply voltage.
E700
Turn off the power and check the input voltage.
Abnormal rise in sewing machine motor drive voltage.
E701
Turn off the power, and then check the voltage.
Abnormal drop in power supply voltage.
E705
Turn off the power and check the input voltage.
Abnormal current detected in sewing machine motor.
E710
Turn off the power, and then check if there are any problems with the sewing machine.
Abnormal current detected in X-feed motor.
E711
Turn off the power, and then check if there are any problems in the X-feed direction.
Abnormal current detected in Y-feed motor.
E712
Turn off the power, and then check if there are any problems in the Y-feed direction.
Abnormal current detected in work clamp motor.
E713
Turn off the power, and then check if there are any problems with the X-feed mechanism, Y-feed mechanism or
work clamp lifter.
External error input (AIRSW) detected.
E730
Turn off the power, and then check the air pressure.
Control box cooling fan does not operate.
E740
Turn off the power, and then check if the cooling fan is blocked with scraps of thread.
Check that connector P22 on the main P.C. board is properly connected.
X-feed motor cooling fan does not operate.
E741
Turn off the power, and then check if the cooling fan is blocked with scraps of thread.
Check that connector P10 on the main P.C. board is properly connected.
Y-feed motor cooling fan does not operate.
E742
Turn off the power, and then check if the cooling fan is blocked with scraps of thread.
Check that connector P10 on the main P.C. board is properly connected.
If an error code that is not listed above appears or if carrying out the specified remedy does not solve the problem,
contact the place of purchase.
Cause and remedy
Cause and remedy
BAS-342G PS
12. TABLE OF ERROR CODES
70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents