8.10.10
CF_P-MANETIME COMMAND
"CF_P-MANETIME_%1"[CR]
COMMAND
"01"-"30"-- Directly set the time by the minute
%1
"UP"------------ Set the time 1 minute longer
"DN"------------ Set the time 1 minute shorter
Set Power management time. (Only valid when it is in the usual Power On
state.)
Details
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
Response
Unacceptable
8.10.11

CF_FANSPEED COMMAND

"CF_FANSPEED_%1"[CR]
COMMAND
"‚ l ‚ ` ‚ w
%1
"‚ m ‚ n ‚ q "------Select normal speed
Change Fan Control speed.
state.)
Details
The value set is stored in EEPROM. When ALL OFF the projector, the
value will return to the original setting.
Acceptable
Response
Unacceptable
8.10.12

CF_KEYDIS COMMAND

"CF_KEYDIS_%1"[CR]
COMMAND
"N/A" --- RC and KEY are available
%1
"RC"
"KEY"
Set bar the use of RC/KEY. (Only valid when it is in the usual Power On
Details
state.)
Acceptable
Response
Unacceptable
8.10.13
CF_FDEFAULT COMMAND
"CF_FDEFAULT_%1"[CR]
COMMAND
%1
"RST"
Details
Set Factory Default. (Only valid when it is in the usual Power On state.)
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"------Select maximum speed
"000"[CR]
"Error Code"[CR]
...Bar the use of RC
...Bar the use of KEY
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
Only valid when it is in the usual Power On