Theory of Operation Ver. 1.0 Nov. 2008
19.2.2
Control conditions
Motor name
DC power supply
fan motor (FM1)
Ozone ventilation
fan motor (FM2)
Condition
Control conditions
• For a predetermined period of time after the power is
turned ON
• For a predetermined period of time after the end of the
ON
(high
Energy save mode
speed)
• At the start of a print cycle (full-speed rotation after a
predetermined period of time of half-speed rotation)
• At the start of pre-drive
• During standby
ON (low
• At the end of a print cycle (half-speed rotation after a
speed)
predetermined period of time of full-speed rotation)
• During the Energy save mode
• When a malfunction occurs
OFF
• During firmware upgrading
• During transport motor drive
ON
• Other than above
OFF
19. Fan control
71