Wiring Diagram - Whirlpool AMD 017 Manual

Essential dual split air conditioner amd 017
Table of Contents

Advertisement

CAUTION:
1. Use an individual power circuit specifically for the air conditioner. As for the wiring method, refer to the
circuit diagram on the inside of the access door .
2. Check that the cable thickness conforms to the power source specification.
3. Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in a wet or moist area.
Cable Specifications
Power cord
Capacity
(Btu/h)
Type
7K,9K,12K
H05VV-F
1.0~1.5mm² X3
H05VV-F
18K
1.5~2.0mm² X3
RVV
24K
H07RN-F

WIRING DIAGRAM

Make sure that the colour of wires of the outdoor unit and the terminal number are the same as those of
the indoor unit.
• Power supply from Indoor unit, including 7K,9K,12K, Model
HEAT PUMP
Indoor unit
Terminal
Yellow/Green
Blue (Gray)
1(N)
Power connecting cord
Brown
2(L)
Black
3(SI)
Evaporator
YE/GN
Indoor unit control board
BN
AC L-IN
BU
AC N-IN
Power supply
Power connecting cord
Normal cross -
Type
sectional area
H07RN-F
H07RN-F
2.5mm² X3
H07RN-F
Outdoor unit
Yellow/Green
Blue (Gray)
Brown
Black
Normal cross -
sectional area
1.0~1.5mm²X3
H05RN-F
1.5mm²X3
H05RN-F
1.5mm²X3(Heat-pump)
H05RN-F
1.5mm²X4(Cooling-only)
Terminal
1(N)
2(L)
3(SI)
22
Power connecting cord 1
Normal cross -
Type
sectional area
0.75mm²X2
(Heat-pump)
0.75mm²X2
(Heat-pump)
0.75mm²X3
(Heat-pump)
Main
power
supply
(Note)
To indoor
To indoor
To outdoor

Hide quick links: