Wiring Diagram - Whirlpool AMD 011 User Manual

Table of Contents

Advertisement

CAUTION:
1. Use an individual power circuit specifically for the air conditioner. As for the wiring method, refer to the
circuit diagram on the inside of the access door .
2. Check that the cable thickness conforms to the power source specification.
3. Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in a wet or moist area.
Cable Specifications
Capacity
(Btu/h)
Type
7K,9K,12K
H05VV-F
H05VV-F
18K
RVV
24K
H07RN-F

WIRING DIAGRAM

Make sure that the colour of wires of the outdoor unit and the terminal number are the same as those of
the indoor unit.
• Power supply from Indoor unit, including 7K,9K,12K, Model
Indoor unit
Terminal
Yellow/Green
Blue (Gray)
1(N)
Brown
2(L)
Black
3(SI)
Evaporator
YE/GN
Indoor unit control board
BN
BU
Power supply
Downloaded from AC-Manual.com Manuals
Power cord
Normal cross -
Type
sectional area
1.0~1.5mm² X3
H07RN-F
1.5~2.0mm² X3
H07RN-F
2.5mm² X3
H07RN-F
HEAT PUMP
Yellow/Green
Blue (Gray)
Brown
Power connecting cord
Black
AC L-IN
AC N-IN
Power connecting cord
Normal cross -
sectional area
1.0~1.5mm²X3
1.5mm²X3
1.5mm²X3(Heat-pump)
1.5mm²X4(Cooling-only)
Outdoor unit
Terminal
1(N)
2(L)
3(SI)
22
Power connecting cord 1
Normal cross -
Type
sectional area
0.75mm²X2
H05RN-F
(Heat-pump)
0.75mm²X2
H05RN-F
(Heat-pump)
0.75mm²X3
H05RN-F
(Heat-pump)
Main
power
supply
(Note)
To indoor
To indoor
To outdoor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents