IBM 884155U User Manual page 130

User manual
Hide thumbs Also See for 884155U:
Table of Contents

Advertisement

Note: See "System replaceable units" on page 144 to determine which components should be replaced by a field
service technician.
Error code/symptom
166-407-001 System Management: Failed
(BMC indicates failure in I2C bus test.)
166-NNN-001 System Management:
Failed (BMC indicates failure in self test
where NNN=300 to 320.)
166-NNN-001 System Management:
Failed (BMC indicates failure in I2C bus
test where NNN=400 to 420 (excluding 412,
414, and 415).)
180-197-000 (SCSI ASPI driver not
installed)
180-361-003
(Failed fan LED test)
180-XXX-000 (Diagnostics LED failure)
180-XXX-001
(Failed front LED panel test)
180-XXX-002
(Failed diagnostics LED panel test)
180-XXX-003
(Failed system board LED test)
180-XXX-005
(Failed SCSI backplane LED test)
201-XXX-0nn
(Failed memory test)
Note: nn = slot number of failing DIMM;
see "System-board internal connectors" on
page 78.
201-XXX-n99
(Multiple DIMM failure, see error text)
Note: n = slot number of failing DIMM pair;
see Table 2 on page 33.
120
xSeries 236 Type 8841: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
1. Disconnect all server and option power cords from the server,
wait 30 seconds, reconnect, and retry.
2. Reflash or update firmware for BMC.
3. Operator information panel cable.
4. Operator information panel.
5. System board.
1. Disconnect all server and option power cords from the server,
wait 30 seconds, reconnect, and retry.
2. Reflash or update firmware for BMC.
3. System board.
1. Disconnect all server and option power cords from the server,
wait 30 seconds, reconnect, and retry.
2. Reflash or update firmware for BMC.
3. System board.
1. Remove RAID adapter, if installed, and rerun test.
2. System board.
1. Fan
2. System board
v Run diagnostics panel LED test for the failing LED.
1. Operator information card
2. System board
1. Operator information card
2. System board
v System board
1. SCSI backplane
2. SCSI backplane cable
3. System board
1. DIMM nn
2. System board
1. Reseat the DIMMs; then, restart the server.
2. Remove the lowest-numbered DIMM pair of those that are identified
and replace it with an identical pair of known good DIMMs; then,
restart the server. Repeat as necessary. If the failures continue after
all identified pairs are replaced, go to step 4.
3. Return the removed DIMMs, one pair at a time, to their original
connectors, restarting the server after each pair, until a pair fails.
Replace each DIMM in the failed pair with an identical known good
DIMM, restarting the server after each DIMM. Replace the failed
DIMM. Repeat step 3 until you have tested all removed DIMMs.
4. (Trained service technician only) Replace the system board.

Advertisement

Table of Contents
loading

This manual is also suitable for:

88410euXseries 236 8841

Table of Contents