Download Print this page

HP 316095-B21 - StorageWorks Edge Switch 2/24 Release Note page 5

Hp storageworks ha-fabric manager release notes, v08.09.01 (aa-rur6j-te, october 2006)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:

Advertisement

Fixes
Table 2
lists issues that have been fixed in HAFM 08.09.01 since the release of HAFM 08.08.00.
Table 2 HAFM 08.09.01 fixes
Description
The Operational Status column does not update correctly when a
McDATA 4Gb SAN Switch is taken offline. Instead of indicating
that the McDATA 4Gb SAN Switch is offline, the status in the
Operation Status column and alert icon (Product List and Topology
view) displays as failed.
Topology view has update problems when the principle switch is
not managed by HAFM and the fabric is segmented. The device
list adjacent to the topology may display the same switch in two
different fabrics or the switch may toggle from one fabric to another,
at a rate of approximately half of the discovery rate (approximately
eight seconds).
In the product List, Domain ID column not getting sorted properly.
Unable to discover switch when IP is reused in a switch swap-out
scenario.
Changing the server time back causes the link to drop or the closes
the Element Manager. When the user attempts to reopen Element
Manager, the following message appears: The link to the
product is not available:
A Preferred Path cannot be enabled intermittently even when the
Domain ID is set to Insistent.
With FICON Management style, the Addresses menu item under
the Configure menu (Configure > Addresses) is not available
in the 6140 Element Manager.
When performing a CTP switch over from either CTP 0 or 1, the entire
Hardware View window is blank until stopping and starting services.
The user is not notified that firmware download on single-CTP system
causes switch to boot the IPL file rather than the current active
configuration.
For an upgrade firmware install, the red progress bar is not updated.
Stopping External port diagnostics in the middle of a test may cause
port to indicate failure.
Firmware may not update on HP-UX systems.
The cooling fan module may display incorrect position information
in the element manager FRU list.
Port status alert indicator may not be removed when a NOS alert
is cleared from Ports tab
No log entries generated when a link between switches is
disconnected.
User Action Event may not be generated in Master log for
modifications done in Call Home dialog.
The HAFM Event Log is missing system power up and standby ready
events after system power down.
When enabling or disabling fabric binding on muliple fabrics, the
wrong WWN displays in the Fabric Name field of the Fabric Binding
Status window.
Connection lost.
Problem Category
Display/Layout/GUI
Display/Layout/GUI
Device List/Properties
Discovery
Element Manager
Element Manager
Element Manager
Element Manager
Element Manager
Element Manager
Element Manager
Element Manager
Element Manager
Element Manager
Event Management
Event Notification
Element Manager
Fabric Binding
HA-Fabric Manager release notes
5

Advertisement

loading