Hsg80 Transparent Mode Not Supported With Ibm Aix - HP 316095-B21 - StorageWorks Edge Switch 2/24 Release Note

Fw 05.01.00 and sw 07.01.00 edge switch release notes
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Certain Unauthorized Devices may Increase Response Time for Fabric
Operations Under Specific Conditions with the Edge Switch 2/24
When Port Binding is enabled, unauthorized devices (devices that are not set up
by the Port Binding) with older technology can transmit numerous fabric login
(FLOGI) requests, which are rejected by the Edge Switch 2/24. Processing these
exchanges may increase fabric response times for activities such as fabric builds
and valid FLOGI response time for other ports.
Workaround
Remove the unauthorized device, change the Port Binding WWN (if this device
should be authorized), or alternatively disable Port Binding.
CTP Events for Edge Switch 2/24 Show Incorrect FRU Number
Should a CTP event occur in an Edge Switch 2/24, the event log may show
"CTP-24" instead of "CTP-0". There is only one CTP in the Edge Switch 2/24, so
there should be no question as to what FRU is exhibiting the event.

HSG80 Transparent Mode Not Supported with IBM AIX

Use of an HSG80 with IBM AIX is restricted to operating the HSG80 in Multibus
mode with the Edge Switch 2/24 and Edge Switch 2/32. Transparent mode is not
supported at this time.
Workaround
None.
Edge Switch Release Notes
Known Issues
17

Advertisement

Table of Contents
loading

Table of Contents